Mfg Part Number: BM-06020 | Alternate P/N: BM06020 | Manufacturer: Aircraft Instruments Company |
NSN : 5945-00-988-0234 | NIIN : 009880234 | Item Name : flasher thermal |
CAGE Code : 09959 | FSC : 5945 Relays and Solenoids |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-988-0234 Item Description: Flasher Thermal | 5945 | 009880234 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Bm-06020 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARA | TERMINAL QUANTITY | 3 |
AARB | TERMINAL TYPE | SOLDER LUG |
ABHP | OVERALL LENGTH | 1.750 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.438 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.594 INCHES NOMINAL |
ACYR | DC VOLTAGE RATING | 20.0 VOLTS MINIMUM AND 32.0 VOLTS MAXIMUM |
ADZC | ENVIRONMENTAL PROTECTION | WATERPROOF AND WATER RESISTANT |
ALGC | MOUNTING CONFIGURATION | MTS BY 4 STUDS NO. 6-32,3/8 IN. LG,ON 1 IN. BY 1 IN. MTG CENTERS |
APCM | ACTUATION TYPE | ELECTROMECHANICAL |
APCS | III ADJUSTABILITY | NONADJUSTABLE |
APFH | FLASHING RATE | 60 PER MINUTE NOMINAL |
APFK | DUTY CYCLE | 1.0 SECONDS ON |
APFM | FAILURE AUTOMATIC CIRCUIT CONDITION | ON |
APFN | ACCURACY IN PERCENT | 5.0 |
APFP | CONTROLLED CIRCUIT QUANTITY | 3 |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |