Mfg Part Number: 6447 | Manufacturer: Electro Impulse Laboratory Inc | NSN : 4820-01-122-9775 |
NIIN : 011229775 | Item Name : valve safety relief | CAGE Code : 91161 |
FSC : 4820 Valves Nonpowered |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
4820-01-122-9775 Item Description: Valve Safety Relief | 4820 | 011229775 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
6447 | 2 | 9 | D |
MRC | Criteria | Characteristic |
---|---|---|
AAJF | THREAD DIRECTION | RIGHT-HAND 1ST END |
ADQU | FLOW CONTROL DEVICE | POPPET |
AEHZ | MAXIMUM OPERATING TEMP | -40.0 DEG FAHRENHEIT 1ST RESPONSE250.0 DEG FAHRENHEIT 2ND RESPONSE |
AHNC | CONNECTION STYLE | PLAIN (PIPE) 1ST END |
AQLR | VALVE OPERATION METHOD | AUTOMATIC |
AWLS | CONNECTION TYPE | THREADED EXTERNAL PIPE 1ST END |
CQGM | MAXIMUM OPERATING PRESSURE | 200.0 POUNDS PER SQUARE INCH SINGLE RESPONSE |
CQJX | NOMINAL THREAD SIZE | 0.250 INCHES 1ST END |
CSDC | OPENING PRESSURE SETTING | 150.0 POUNDS PER SQUARE INCH |
FEAT | SPECIAL FEATURES | POP-OFF TYPE |
MATT | MATERIAL | COPPER ALLOY OVERALL |
MEDA | MEDIA FOR WHICH DESIGNED | AIR 1ST RESPONSE |
MEDA | MEDIA FOR WHICH DESIGNED | ALCOHOL, ETHYL 2ND RESPONSE |
MEDA | MEDIA FOR WHICH DESIGNED | AMMONIA, GASEOUS 3RD RESPONSE |
MEDA | MEDIA FOR WHICH DESIGNED | HYDROGEN 5TH RESPONSE |
MEDA | MEDIA FOR WHICH DESIGNED | REFRIGERANT 12 4TH RESPONSE |
STYL | STYLE DESIGNATOR | STRAIGHT THRU NOTE: TO BE USED FOR VALVE BODIES OF ONE SECTION ONLY. |
THSD | THREAD SERIES DESIGNATOR | NPT 1ST END |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote