Mfg Part Number: 40-000818-01 | Alternate P/N: 4000081801 | Manufacturer: Pacific Instruments Inc |
NSN : 5950-00-021-3816 | NIIN : 000213816 | Item Name : transformer power |
CAGE Code : 06931 | FSC : 5950 Coils and Transformers |
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-021-3816 Item Description: Transformer Power | 5950 | 000213816 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
40-000818-01 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABTB | MOUNTING HOLE DIAMETER | 0.219 INCHES MAXIMUM SINGLE GROUP |
ACZB | FREQUENCY RATING | 640.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.190 INCHES NOMINAL |
ADAR | BODY OUTSIDE DIAMETER | 2.540 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 40.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 666.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 8.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 90.50 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 10 TURRET |